文章摘要:
Hydraulic
diagram drawing for the ring-shaped networkof multi-heat
sources
By Zhao Wenbin,
Yao Yixian and Huang Xiaofei
Abstract Bas......
Hydraulic
diagram drawing for the ring-shaped network of multi-heat
sources
By Zhao Wenbin,
Yao Yixian and Huang Xiaofei
Abstract Based on built projects, introduces
methods for hydraulic calculation whereby to adjust joint flow
distribution for optimum regime and automatically generate hydraulic
drawings for complicated ring-shaped network of multi-heat sources
by the computer. Keywords multi-heat sources,
ring-shaped network, balance point, hydraulic calculation, hydraulic
diagram
1 引言 随着科学技术的进步和城市供热的迅速发展,热网的规模不断扩大,自动化水平不断提高,多热源联网将会成为城市供热的一个发展趋势。多热源联网有利于提高供热的经济性和安全可靠性,有利于热网调度的灵活性,同时有利于供热系统近、远期发展的结合,能更好地适应城市建设的发展需求。但在多热源联网的情况下,供热系统的水力工况、热力工况及调节工况变得很复杂,如何快速、准确地绘制水压图,是优化联网运行方案的一项重要工作。下面结合包头市的集中供热热网,谈谈多热源联网水压图的绘制方法。
2 包头市集中供热概况 包头市自1990年以来集中供热,供热规模不断扩大,到1998~1999年供暖期供热面积达到470万
m2,热力站共63座,大部分为直接连接方式。供热热源有3个,热源A由3台100
MW汽轮发电机抽汽供热,热源B,C分别装设4台29
MW热水锅炉。三热源供热管网已联网,并形成了环形管网。其热源位置、管网布局及负荷分布情况如图1所示。

图1 管网平面布置图
节点处数值为供热面积分配值,D/L-管径(mm)/长度(m),S点为定压点,S17,W13为平衡点汇交点,平衡点—热力站及支线
3 水力计算前的准备工作 3.1 原始参数 ①热源的供热能力、供热方式、介质参数、循环水泵性能参数等。 ②热用户的热负荷分布及其性质。 ③地形图。包括热用户、水泵站及热源点的地坪标高,高层建筑的位置及标高等。 3.2 绘制管网平面图 管网平面图应包括热源参数、介质参数、定压点位置,各管段自然长度、管道内径、管道附件,热负荷分布等。并初步进行供热系统的热量平衡,划出各热源的供热范围,拟定水力平衡点,示出各管段水流方向、汇合点的流量分配情况。
4 水力计算 4.1 数学模型 ①管道直管段摩擦阻力损失: Δpf=Rl 其中
< [1] [2] [3] 下一页